Fire rated door technical data
A reference page for consultants, specifiers and procurement teams. All values are taken from the product technical documents.
- 63mm Leaf thickness
- 1.2mm Galvanized leaf skin
- 1.8mm Galvanized frame
- 2 Security bolts per leaf
- 3 Piece frame
- 10 Frame fixing points
Fire resistance classification
| Door type | Integrity (E) | Insulation (EI2) | Insulation (EI1) |
|---|---|---|---|
| Single-leaf door | E120 | EI260 | EI130 |
| Double-leaf door | E90 | EI245 | EI120 |
Values in minutes. Tested to EN 1634-1:2014+A1:2018
Key specifications
- Leaf thickness
- 63 mm
- Leaf skin
- 1.2 mm galvanized steel
- Frame
- 1.8 mm galvanized steel, 3-piece
- Fixing
- 10 anchor points into the wall, no additional sub-frame
- Fire seal
- Intumescent strip fitted on the frame
- Hinges
- Heavy-duty ball-bearing hinges, one self-closing
- Security
- Two hinge-side bolts per leaf
- Finish
- Electrostatic powder coating, RAL 9002 standard, any RAL colour on request
- Handing
- Reversible, left or right
- Hardware
- Compatible with panic bars and electromagnetic locks
Available sizes
| Type | Width | Height |
|---|---|---|
| Single-leaf door | 80 / 90 / 100 / 110 / 120 cm | 220 cm |
| Double-leaf door | 120 / 140 / 160 / 180 / 200 cm | 220 cm |
Horizontal section through the door

Finish & colours
Electrostatic powder coating on leaf and frame.
- RAL 9002 Standard colour
- RAL Any other catalogue colour on request
Reading the classification
- E — integrity: minutes during which the door prevents flames and hot gases from passing.
- EI — integrity plus insulation: the unexposed face also stays within the permitted temperature rise.
- EI1 is a stricter insulation criterion than EI2, so the same door achieves a shorter EI1 time.
Warning: the double-leaf door is E90 but its insulation is EI2 45. Always state the full classification code in the specification.
Sample BOQ item description
The following description can be used as a starting point, adjusted for size and rating:
Supply and install single-leaf steel fire rated door, tested to EN 1634-1:2014+A1:2018, classification E120 / EI2 60; 63 mm leaf with 1.2 mm galvanized steel skins; 3-piece 1.8 mm galvanized steel frame; intumescent seal on frame; ball-bearing hinges incl. one self-closing hinge; two hinge-side bolts; electrostatic powder coating RAL 9002; structural opening 1000 × 2200 mm.