What a fire rated door does
A fire rated door is part of a building’s passive fire protection. It keeps a fire inside the compartment where it starts, limits the spread of flames and hot smoke, and buys time for evacuation and response.
A door’s value is its classification, not its appearance or skin thickness alone. The classification comes from a furnace test of the complete assembly — leaf, frame, hinges and seals — and states how many minutes the door met each performance criterion.
Construction
- 63 mm leaf with 1.2 mm galvanized steel skins
- 1.8 mm galvanized steel frame, 3-piece
- Intumescent strip on the frame that expands with heat to seal the gap
- Heavy-duty ball-bearing hinges, one self-closing
- Two hinge-side bolts per leaf
- Electrostatic powder coating
Typical locations in a factory
- Electrical rooms and switchgear rooms
- Generator and compressor rooms
- Stores holding combustible materials
- Stair cores and protected escape routes
- Separation between production areas
- Exit routes — see emergency exit doors
What to send for an accurate quotation
| Item | Details |
|---|---|
| Quantity | Number of doors per size |
| Type | Single-leaf or double-leaf |
| Size | Structural opening width and height |
| Required rating | As per project specification or consultant |
| Handing | Left or right, inward or outward |
| Hardware | Panic bar, magnetic lock, others |
| Colour | Standard or RAL reference |
| Location | Site location for installation |
If you have a door schedule, BOQ or architectural drawings, send them directly and we will take the data from them.